Publication Conditioning of aluminium-based water treatment sludge with Fenton’s reagent : effectiveness and optimising study to improve dewaterabilityAlternative conditioning of aluminium-based drinking water treatment sludge using Fenton reagent (Fe2+/H2O2) was examined in this study. Focuses were placed on effectiveness and factors to affect such novel application of Fenton process. Experiments have demonstrated that considerable improvement of alum sludge dewaterability evaluated by capillary suction time (CST) can be obtained at the relative low concentrations of Fenton reagent. A Box-Behnken experimental design based on the response surface methodology was applied to evaluate the optimum of the influencing variables, i.e. iron concentration, hydrogen peroxide concentration and pH. The optimal values for Fe2+, H2O2, and pH are 21 mg g-1 DS-1(dry solids), 105 mg g-1 DS-1 and 6, respectively, at which the CST reduction efficiency of 48±3 % can be achieved, this agreed with that predicted by an established polynomial model in this study.2106Scopus© Citations 138