Now showing 1 - 4 of 4
  • Publication
    A Wearable Sensor-Based Exercise Biofeedback System: Mixed Methods Evaluation of Formulift
    Background: Formulift is a newly developed mobile health (mHealth) app that connects to a single inertial measurement unit (IMU) worn on the left thigh. The IMU captures users movements as they exercise, and the app analyzes the data to count repetitions in real time and classify users exercise technique. The app also offers feedback and guidance to users on exercising safely and effectively. Objective: The aim of this study was to assess the Formulift system with three different and realistic types of potential users (beginner gym-goers, experienced gym-goers, and qualified strength and conditioning [S&C] coaches) under a number of categories: (1) usability, (2) functionality, (3) the perceived impact of the system, and (4) the subjective quality of the system. It was also desired to discover suggestions for future improvements to the system. Methods: A total of 15 healthy volunteers participated (12 males; 3 females; age: 23.8 years [SD 1.80]; height: 1.79 m [SD0.07], body mass: 78.4 kg [SD 9.6]). Five participants were beginner gym-goers, 5 were experienced gym-goers, and 5 were qualified and practicing S&C coaches. IMU data were first collected from each participant to create individualized exercise classifiers for them. They then completed a number of non exercise-related tasks with the app. Following this, a workout was completed using the system, involving squats, dead lifts, lunges, and single-leg squats. Participants were then interviewed about their user experience and completed the System Usability Scale (SUS) and the user version of the Mobile Application Rating Scale (uMARS). Thematic analysis was completed on all interview transcripts, and survey results were analyzed. Results: Qualitative and quantitative analysis found the system has good to excellent usability. The system achieved a mean (SD) SUS usability score of 79.2 (8.8). Functionality was also deemed to be good, with many users reporting positively on the systems repetition counting, technique classification, and feedback. A number of bugs were found, and other suggested changes to the system were also made. The overall subjective quality of the app was good, with a median star rating of 4 out of 5 (interquartile range, IQR: 3-5). Participants also reported that the system would aid their technique, provide motivation, reassure them, and help them avoid injury. Conclusions: This study demonstrated an overall positive evaluation of Formulift in the categories of usability, functionality, perceived impact, and subjective quality. Users also suggested a number of changes for future iterations of the system. These findings are the first of their kind and show great promise for wearable sensor-based exercise biofeedback systems.
      451Scopus© Citations 16
  • Publication
    Technology in Rehabilitation: Evaluating the Single Leg Squat Exercise with Wearable Inertial Measurement Units
    Background: The single leg squat (SLS) is a common lower limb rehabilitation exercise. It is also frequently used as an evaluative exercise to screen for an increased risk of lower limb injury. To date athlete / patient SLS technique has been assessed using expensive laboratory equipment or subjective clinical judgement; both of which are not without shortcomings. Inertial measurement units (IMUs) may offer a low cost solution for the objective evaluation of athlete / patient SLS technique. Objectives: The aims of this study were to determine if in combination or in isolation IMUs positioned on the lumbar spine, thigh and shank are capable of: (a) distinguishing between acceptable and aberrant SLS technique; (b) identifying specific deviations from acceptable SLS technique. Methods: Eighty-three healthy volunteers participated (60 males, 23 females, age: 24.68 + / − 4.91 years, height: 1.75 + / − 0.09 m, body mass: 76.01 + / − 13.29 kg). All participants performed 10 SLSs on their left leg. IMUs were positioned on participants’ lumbar spine, left shank and left thigh. These were utilized to record tri-axial accelerometer, gyroscope and magnetometer data during all repetitions of the SLS. SLS technique was labelled by a Chartered Physiotherapist using an evaluation framework. Features were extracted from the labelled sensor data. These features were used to train and evaluate a variety of random-forests classifiers that assessed SLS technique. Results: A three IMU system was moderately successful in detecting the overall quality of SLS performance (77 % accuracy, 77 % sensitivity and 78 % specificity). A single IMU worn on the shank can complete the same analysis with 76 % accuracy, 75 % sensitivity and 76 % specificity. Single sensors also produce competitive classification scores relative to multi-sensor systems in identifying specific deviations from acceptable SLS technique. Conclusions: A single IMU positioned on the shank can differentiate between acceptable and aberrant SLS technique with moderate levels of accuracy. It can also capably identify specific deviations from optimal SLS performance. IMUs may offer a low cost solution for the objective evaluation of SLS performance. Additionally, the classifiers described may provide useful input to an exercise biofeedback application.
      874Scopus© Citations 35
  • Publication
    Technology in Rehabilitation: Comparing Personalised and Global Classification Methodologies in Evaluating the Squat Exercise with Wearable IMUs
    BACKGROUND: The barbell squat is a popularly used lower limb rehabilitation exercise. It is also an integral exercise in injury risk screening protocols. To date athlete/patient technique has been assessed using expensive laboratory equipment or subjective clinical judgement; both of which are not without shortcomings. Inertial measurement units (IMUs) may offer a low cost solution for the objective evaluation of athlete/patient technique. However, it is not yet known if global classification techniques are effective in identifying naturally occurring, minor deviations in barbell squat technique.OBJECTIVES: The aims of this study were to: (a) determine if in combination or in isolation, IMUs positioned on the lumbar spine, thigh and shank are capable of distinguishing between acceptable and aberrant barbell squat technique; (b) determine the capabilities of an IMU system at identifying specific natural deviations from acceptable barbell squat technique; and (c) compare a personalised (N=1) classifier to a global classifier in identifying the above. METHODS: Fifty-five healthy volunteers (37 males, 18 females, age = 24.21 +/- 5.25 years, height = 1.75 +/- 0.1 m, body mass = 75.09 +/- 13.56 kg) participated in the study. All participants performed a barbell squat 3-repetition maximum max strength test. IMUs were positioned on participants' lumbar spine, both shanks and both thighs; these were utilized to record tri-axial accelerometer, gyroscope and magnetometer data during all repetitions of the barbell squat exercise. Technique was assessed and labelled by a Chartered Physiotherapist using an evaluation framework. Features were extracted from the labelled IMU data. These features were used to train and evaluate both global and personalised random forests classifiers.RESULTS: Global classification techniques produced poor accuracy (AC), sensitivity (SE) and specificity (SP) scores in binary classification even with a 5 IMU set-up in both binary (AC: 64%, SE: 70%, SP: 28%) and multi-class classification (AC: 59%, SE: 24%, SP: 84%). However, utilising personalised classification techniques even with a single IMU positioned on the left thigh produced good binary classification scores (AC: 81%, SE: 81%, SP: 84%) and moderate-to-good multi-class scores (AC: 69%, SE: 70%, SP: 89%).CONCLUSIONS: There are a number of challenges in developing global classification exercise technique evaluation systems for rehabilitation exercises such as the barbell squat. Building large, balanced data sets to train such systems is difficult and time intensive. Minor, naturally occurring deviations may not be detected utilising global classification approaches. Personalised classification approaches allow for higher accuracy and greater system efficiency for end-users in detecting naturally occurring barbell squat technique deviations. Applying this approach also allows for a single-IMU set up to achieve similar accuracy to a multi-IMU setup, which reduces total system cost and maximises system usability.
      522Scopus© Citations 12
  • Publication
    Mobile App to Streamline the Development of Wearable Sensor-Based Exercise Biofeedback Systems: System Development and Evaluation
    Background: Biofeedback systems that use inertial measurement units (IMUs) have been shown recently to have the ability toobjectively assess exercise technique. However, there are a number of challenges in developing such systems; vast amounts ofIMU exercise datasets must be collected and manually labeled for each exercise variation, and naturally occurring techniquedeviations may not be well detected. One method of combatting these issues is through the development of personalized exercisetechnique classifiers.Objective: We aimed to create a tablet app for physiotherapists and personal trainers that would automate the development ofpersonalized multiple and single IMU-based exercise biofeedback systems for their clients. We also sought to complete apreliminary investigation of the accuracy of such individualized systems in a real-world evaluation.Methods: A tablet app was developed that automates the key steps in exercise technique classifier creation through synchronizingvideo and IMU data collection, automatic signal processing, data segmentation, data labeling of segmented videos by an exerciseprofessional, automatic feature computation, and classifier creation. Using a personalized single IMU-based classification system,15 volunteers (12 males, 3 females, age: 23.8 [standard deviation, SD 1.8] years, height: 1.79 [SD 0.07] m, body mass: 78.4 [SD9.6] kg) then completed 4 lower limb compound exercises. The real-world accuracy of the systems was evaluated.Results: The tablet app successfully automated the process of creating individualized exercise biofeedback systems. Thepersonalized systems achieved 89.50% (1074/1200) accuracy, with 90.00% (540/600) sensitivity and 89.00% (534/600) specificityfor assessing aberrant and acceptable technique with a single IMU positioned on the left thigh.Conclusions: A tablet app was developed that automates the process required to create a personalized exercise techniqueclassification system. This tool can be applied to any cyclical, repetitive exercise. The personalized classification model displayedexcellent system accuracy even when assessing acute deviations in compound exercises with a single IMU.
      429