    The Evolving Dynamic Response of a Four Storey Reinforced Concrete Structure During Construction
    Structures include elements designated as load bearing and non-load bearing. While non-load bearing elements, such as facades and internal partitions, are acknowledged to add mass to the system, the structural stiffness and strength is generally attributed to load bearing elements only. This paper investigates the contribution of non-load bearing elements to the dynamic response of a new structure, the Charles Institute, in the grounds of University College Dublin (UCD) Ireland. The vertical vibration response of the first floor and the lateral response at each floor level were recorded at different construction stages. The evolution of the structural response as well as the generation of a finite element (FE) model is discussed. It was found that the addition of the non-load bearing facades increased the first floor natural frequency from 10.7 Hz to 11.4?Hz, a change of approximately +6.5%. Similarly these external facades resulted in the first sway mode having its frequency increased by 6%. The subsequent addition of internal partitions, mechanical services and furnishings resulted in the floor natural frequency reducing to 9.2 Hz. It is concluded that external facades have the net effect of adding stiffness and the effect of internal partitions and furnishings is to add mass. In the context of finite element modelling of structures there is a significant challenge to represent these non-structural elements correctly so as to enable the generation of truly predictive FE models.
    Scopus© Citations 14  525