Repository logo
  • Log In
    New user? Click here to register.Have you forgotten your password?
University College Dublin
  • Colleges & Schools
  • Statistics
  • All of DSpace
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. College of Science
  3. School of Computer Science
  4. Computer Science Research Collection
  5. Lower body reaction testing using ultrasonic motion capture
 
  • Details
Options

Lower body reaction testing using ultrasonic motion capture

File(s)
FileDescriptionSizeFormat
Download Lower_Body_Reaction_Testing_Using_Ultrasonic_Motion_Capture.pdf1.88 MB
Author(s)
Taylor, Ken 
Lennon, Olive 
Blake, Catherine 
Fitzgerald, Diarmaid 
Fox, Domhnaill 
Bleakley, Chris J. 
Uri
http://hdl.handle.net/10197/7088
Date Issued
30 August 2014
Date Available
23T15:19:30Z September 2015
Abstract
This paper presents a lower body reaction test that utilizes a new portable ultra-sound based motion capture system (MobiFit) combined with a synchronized visual stimulus. This novel system was tested first for criterion validity and agreement against a gold standard laboratory based optical motion capture system (CODA). It was subsequently tested in the field during Gaelic football (GAA) team gym sessions with 35 subjects to demonstrate its utility and versatility. The lower body reaction test itself is novel in that it can be applied to a gross motor task. During testing, participants had sensors attached to their lower limbs and trunk. The speed of movement for each sensor was monitored at 500Hz using the Mobifit motion capture system, and reaction time was measured as the elapsed time from the appearance of a green indicator on the screen to a sensor reaching a set threshold velocity as the participant raised the corresponding leg. Pearson's correlation coefficient tested criterion validity against the CODA system and Intra class correlation coefficients and Bland-Altman plots assessed agreement of velocity measures obtained from the MobiFit and CODA systems. Results indicate that the MobiFit system is an accurate device to assess lower body reaction time and has advantage over standard laboratory measures in terms of portability and ease of set-up.
Sponsorship
Enterprise Ireland
Type of Material
Conference Publication
Publisher
IEEE
Copyright (Published Version)
2014 IEEE
Keywords
  • Biomechanics

  • Biomedical measuremen...

  • Biomedical ultrasonic...

  • Motion measurement

DOI
10.1109/EMBC.2014.6943649
Language
English
Status of Item
Peer reviewed
Description
2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Chicago, USA, 26 - 30 August 2014
This item is made available under a Creative Commons License
https://creativecommons.org/licenses/by-nc-nd/3.0/ie/
Owning collection
Computer Science Research Collection
Scopus© citations
0
Acquisition Date
Feb 5, 2023
View Details
Views
1658
Last Week
1
Last Month
3
Acquisition Date
Feb 5, 2023
View Details
Downloads
391
Last Month
74
Acquisition Date
Feb 5, 2023
View Details
google-scholar
University College Dublin Research Repository UCD
The Library, University College Dublin, Belfield, Dublin 4
Phone: +353 (0)1 716 7583
Fax: +353 (0)1 283 7667
Email: mailto:research.repository@ucd.ie
Guide: http://libguides.ucd.ie/rru

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement