Objective quantification of a clinical dynamic balance assessment

Author(s)
Johnston, William  
Moran, Thomas  
Dolan, Kara  
Reid, Niamh  
Caulfield, Brian  
Uri
http://hdl.handle.net/10197/9650
Date Issued
2017-05-25
Date Available
2019-03-21T15:39:37Z
Abstract
Objective: To investigate whether addition of inertial sensor data can provide additional insight into the nature of postural stability deficits during a clinical dynamic balance assessment, with a view to enhancing accuracy of post-concussion monitoring protocols. Design: Descriptive laboratory study. Setting: University performance laboratory. Participants: Fifteen physically active adults (age 234 years, height 1758 cm, weight 67.58 kg). Interventions: An inertial measurement unit (IMU) was mounted at the level of the 4th lumbar vertebra. Subjects completed repeated Y-Balance tests (YBT) 10 minutes and immediately prior to a modified 60 second Wingate anaerobic fatiguing test. Post-fatigue YBTs were completed immediately following the test, and at 10 and 20 minutes.Outcome measures: Normalised YBT reach distances, and IMU derived RMS acceleration, velocity and angular velocity. Main results: Prior to the fatiguing intervention, participants demonstrated excellent stability/reliability for all reach directions (Intra-class correlation coefficient 0.872-0.994). Significantly lower reach distances (P<0.05) were observed immediately post-fatigue for the postero-medial and postero-lateral, but not anterior reach direction. Observed deficits returned to pre-fatigue levels by 10 minutes. However, IMU derived measures of postural stability remained significantly reduced (P<0.05) for up to 20 minute post-fatigue. Conclusions: These results demonstrate the ability of both traditional YBT reach distances and inertial sensor data to detect centrally driven postural stability deficits. However, the inertial sensor provided a greater degree of granularity in characterising the nature of these postural stability deficits. This suggests that addition of IMUs to clinical balance measurement tests/protocols may better detect deficits associated with concussion.
Sponsorship
Science Foundation Ireland
Type of Material
Journal Article
Publisher
BMJ
Journal
British Journal of Sports Medicine
Volume
51
Issue
11
Start Page
A54
End Page
A55
Copyright (Published Version)
2017 BMJ Publishing Group Limited
Subjects

Inertial sensor data

Postural stability de...

Clinical balance asse...

Post-concussion proto...

Y-Balance tests

Wingate anaerobic fat...

DOI
10.1136/bjsports-2016-097270.142
Web versions
10.5220/0006079400150024
Language
English
Status of Item
Peer reviewed
This item is made available under a Creative Commons License
https://creativecommons.org/licenses/by-nc-nd/3.0/ie/
File(s)
No Thumbnail Available
Name

insight_publication.pdf

Size

113.49 KB

Format

Adobe PDF

Checksum (MD5)

cb47eb5c90cc89b908c7488977812a84

Owning collection
Insight Research Collection

Item descriptive metadata is released under a CC-0 (public domain) license: https://creativecommons.org/public-domain/cc0/.
All other content is subject to copyright.

For all queries please contact research.repository@ucd.ie.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement