Options
Assessment and code considerations for the combined effect of seismic base-isolation and viscoelastic dampers
Author(s)
Date Issued
2011
Date Available
2012-05-11T15:55:57Z
Abstract
To propose an initial formulation for the passive control section of the Turkish Earthquake Code, the impact of base isolation and viscoelastic dampers on a four-story reinforced concrete (RC) frame building was considered under various one-dimensional earthquake excitations. Both statically equivalent seismic load methods (comparing Turkish Earthquake code with Uniform Building Code) and linear time history analyses were applied to the RC building based on a portion of the 1999 Kocaeli Earthquake ground motion record (modified to possess predominant spectral periods of T1=0.13 sec and T2=1.43 sec). Effective peak ground acceleration was set to 0.40g representing hard and soft soil conditions, respectively. Time history variations of upper column displacements and bending moments were compared, as well as story drift ratios. Reductions of the fixed-base case displacements and column bending moments were obtained of up to 73% under base-isolation, up to 25% with viscoelastic dampers, and up to 83% (with a unified response reduction factor) when both devices were both present.
Sponsorship
Not applicable
Type of Material
Journal Article
Publisher
Hindawi Publishing Corporation
Journal
ISRN Civil Engineering
Volume
2011
Issue
2011
Copyright (Published Version)
2011 Aykut Erkal et al.
Subject – LCSH
Viscoelasticity
Damping (Mechanics)
Earthquake resistant design
Language
English
Status of Item
Peer reviewed
This item is made available under a Creative Commons License
File(s)
Loading...
Name
open repository version.pdf
Size
4.63 MB
Format
Adobe PDF
Checksum (MD5)
a759e88638471a128e691ae041ec4d0b
Owning collection
Mapped collections