Abstract
This paper showcases the importance of field testing in efforts to deal with the deteriorating infrastructure. It demonstrates a load test performed on a healthy but aging composite reinforced concrete bridges in Exeter, UK. The bridge girders were instrumented with strain transducers and static strains were recorded while a four-axle, 32 tonne lorry remained stationary in a single lane. The results obtained from the field test were used to calculate transverse load distribution factors (DFs) of the deck structure for each loading case. Additionally, a 3-D finite element model of the bridge was developed and calibrated based on field test data. Similar loading cases were simulated on the analytical model and behaviour of the structure under static loading was studied. It was concluded that the bridge support conditions had changed throughout its service life, which affected the superstructure load distribution characteristics. Finally, DFs obtained from analysis were compared with factors provided in Design Manual for Roads and Bridges Standard Specification for similar type of bridges.
Other Sponsorship
European Union’s Horizon 2020
Marie Skłodowska–Curie grant
Type of Material
Conference Publication
Publisher
Queen's University Belfast
Web versions
Language
English
Status of Item
Peer reviewed
Description
Proceedings of the CSHM-6: Structural Health Monitoring of New and Ageing Infrastructure, Queen's University Belfast, Northern Ireland, United Kingdom, 26-27 May 2016
This item is made available under a Creative Commons License
Owning collection
Views
2189
Last Week
2
2
Last Month
2
2
Acquisition Date
Mar 30, 2023
Mar 30, 2023
Downloads
1246
Last Week
1
1
Last Month
4
4
Acquisition Date
Mar 30, 2023
Mar 30, 2023