Abstract
This paper presents a generic foreground calibration algorithm that estimates and corrects memoryless nonlinear impairments in both single channel and time-interleaved analog-to-digital converters (TIADCs), and which is capable of correcting for amplifier nonlinearity, comparator offsets, and capacitance mismatch for each channel. It operates by generating, and then using, a look-up table which maps raw ADC output decision vectors to linearized output. For TIADCs, the algorithm also uses information gained during the calibration phase to estimate timing and gain mismatches among the sub-ADCs. The problem of selecting an appropriate timing reference so as to relax the requirements on the time-skew correction circuitry is statistically analyzed, as is the corresponding impact on manufacturing yield. Accordingly, a new method is proposed having superior performance; for example, in the case of an eight sub-ADC TIADC system, the proposed scheme reduces the time skew correction requirement by 44% compared with conventional methods. The architecture is instrumented with some additional circuitry to facilitate built-in self-test, allowing manufacturing test time and cost reductions. Implementation aspects are discussed, and several complexity reduction techniques are presented along with synthesis results from a Verilog implementation of the calibration engine.
Sponsorship
European Commission Horizon 2020
Science Foundation Ireland
Type of Material
Journal Article
Publisher
IEEE
Journal
IEEE Transactions on Circuits and Systems I: Regular Papers
Volume
66
Issue
5
Start Page
1874
End Page
1885
Copyright (Published Version)
2018 IEEE
Subjects

ADC

Transfer function

Foreground

Calibration

Nonlinearity

TIADC

BIST

Bandwidth mismatch

DOI
10.1109/TCSI.2018.2870529
Language
English
Status of Item
Peer reviewed
ISSN
1549-8328
This item is made available under a Creative Commons License
https://creativecommons.org/licenses/by-nc-nd/3.0/ie/
File(s)
Loading...
Thumbnail Image
Name

adcChar_j.pdf

Size

1.43 MB

Format

Adobe PDF

Checksum (MD5)

c656bfdccdbf5bc8bc6eab46e6f88a32

Owning collection
Electrical and Electronic Engineering Research Collection

Item descriptive metadata is released under a CC-0 (public domain) license: https://creativecommons.org/public-domain/cc0/.
All other content is subject to copyright.

For all queries please contact research.repository@ucd.ie.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement