Options
Impact of Implementing Preanalytical Laboratory Standards on the Diagnosis of Gestational Diabetes Mellitus: A Prospective Observational Study
Date Issued
2016-02
Date Available
2016-12-04T02:00:46Z
Abstract
Background: Gestational diabetes mellitus (GDM) is associated with adverse pregnancy outcomes, but risk is reduced with identification and early treatment. Glucose measurements are affected by preanalytical sample handling, such as temperature of storage, phlebotomy–analysis interval, and use of a glycolysis inhibitor. We evaluated glucose concentrations and the incidence of GDM after strict implementation of the American Diabetes Association (ADA) preanalytical guidelines, compared with usual hospital conditions. Methods: Women screened selectively for GDM at 24 –32 weeks’ gestation were recruited at their convenience before a 75-g oral glucose tolerance test. Paired samples were taken: the first sample followed ADA recommendations and was transferred to the laboratory on an iced slurry for immediate separation and analysis (research conditions), and the second sample was not placed on ice and was transferred according to hospital practice (usual conditions). Results: Of samples from 155 women, the mean fasting, 1-h, and 2-h results were 90.0 (12.6) mg/dL [5.0 (0.7) mmol/L], 142.2 (43.2) mg/dL [7.9 (2.4) mmol/L], and 102.6 (32.4) mg/dL [5.7 (1.8) mmol/L], respectively, under research conditions, and 81 (12.6) mg/dL [4.5 (0.7) mmol/L], 133.2 (41.4) mg/dL [7.4 (2.3) mmol/L], and 99 (32.4) mg/dL [5.5 (1.8) mmol/L] under usual conditions (all P 0.0001). GDM was diagnosed in 38.1% (n 59) under research conditions and 14.2% (n 22) under usual conditions (P 0.0001). The phlebotomy–analysis interval for the fasting, 1-h, and 2-h samples was 20 (9), 17 (10), and 17 (9) min under research conditions and 162 (19), 95 (23), and 32 (19) min under usual conditions (all P 0.0001). All cases of GDM were diagnosed on fasting or 1-h samples; the 2-h test diagnosed no additional cases. Conclusions: Implementation of ADA preanalytical glucose sample handling recommendations resulted in higher mean glucose concentrations and 2.7-fold increased detection of GDM compared with usual hospital practices.
Type of Material
Journal Article
Publisher
American Association for Clinical Chemistry
Journal
Clinical Chemistry
Volume
62
Issue
2
Start Page
387
End Page
391
Copyright (Published Version)
2015 American Association for Clinical Chemistry
Language
English
Status of Item
Peer reviewed
This item is made available under a Creative Commons License
File(s)
Loading...
Name
Impact_of_Implementing_Preanalytical_Laboratory_Standards_on_the_Diagnosis_of_Gestational_Diabetes_Mellitus_A_Prospective_Observational_Study.pdf
Size
750.32 KB
Format
Adobe PDF
Checksum (MD5)
eab4c177f0ad2169bd3f3559eb624091
Owning collection