Whole body oxygen uptake and evoked knee torque in response to low frequency electrical stimulation of the quadriceps muscles: V O2 frequency response to NMES

Files in This Item:
File Description SizeFormat 
insight_publication.pdf1.06 MBAdobe PDFDownload
Title: Whole body oxygen uptake and evoked knee torque in response to low frequency electrical stimulation of the quadriceps muscles: V O2 frequency response to NMES
Authors: Minogue, Conor
Caulfield, Brian
Lowery, Madeleine M.
Permanent link: http://hdl.handle.net/10197/6554
Date: 28-Jun-2013
Abstract: Background: There is emerging evidence that isometric Neuromuscular Electrical Stimulation (NMES) may offer a way to elicit therapeutically significant increases in whole-body oxygen uptake in order to deliver aerobic exercise to patients unable to exercise volitionally, with consequent gains in cardiovascular health. The optimal stimulation frequency to elicit a significant and sustained pulmonary oxygen uptake has not been determined. The aim of this study was to examine the frequency response of the oxygen uptake and evoked torque due to NMES of the quadriceps muscles across a range of low frequencies spanning the twitch to tetanus transition. Methods: Ten healthy male subjects underwent bilateral NMES of the quadriceps muscles comprising eight 4 minute bouts of intermittent stimulation at selected frequencies in the range 1 to 12 Hz, interspersed with 4 minutes rest periods. Respiratory gases and knee extensor torque were simultaneously monitored throughout. Multiple linear regression was used to fit the resulting data to an energetic model which expressed the energy rate in terms of the pulse frequency, the torque time integral and a factor representing the accumulated force developed per unit time. Results: Additional oxygen uptake increased over the frequency range to a maximum of 564 (SD 114) ml min-1 at 12 Hz, and the respiratory exchange ratio was close to unity from 4 to 12 Hz. While the highest induced torque occurred at 12 Hz, the peak of the force development factor occurred at 6 Hz. The regression model accounted for 88% of the variability in the observed energetic response. Conclusions: Taking into account the requirement to avoid prolonged tetanic contractions and to minimize evoked torque, the results suggest that the ideal frequency for sustainable aerobic exercise is 4 to 5 Hz, which coincided in this study with the frequency above which significant twitch force summation occurred.
Funding Details: Science Foundation Ireland
Type of material: Journal Article
Publisher: BioMed Central
Copyright (published version): 2013 the Authors
Keywords: Optimisation;Decision analytics;Electrical stimulation;Metabolic response;Muscle energetics
DOI: 10.1186/1743-0003-10-63
Language: en
Status of Item: Peer reviewed
Appears in Collections:Electrical and Electronic Engineering Research Collection
Public Health, Physiotherapy and Sports Science Research Collection
Insight Research Collection

Show full item record

SCOPUSTM   
Citations 50

6
Last Week
1
Last month
checked on Jun 22, 2018

Page view(s) 50

60
checked on May 25, 2018

Download(s) 20

291
checked on May 25, 2018

Google ScholarTM

Check

Altmetric


This item is available under the Attribution-NonCommercial-NoDerivs 3.0 Ireland. No item may be reproduced for commercial purposes. For other possible restrictions on use please refer to the publisher's URL where this is made available, or to notes contained in the item itself. Other terms may apply.