Development of a synthetic phantom for the selection of optimal scanning parameters in CAD-CT colonography

Files in This Item:
File Description SizeFormat 
TC_MEP_2007.pdf403.66 kBAdobe PDFDownload
Title: Development of a synthetic phantom for the selection of optimal scanning parameters in CAD-CT colonography
Authors: Chowdhury, Tarik A.
Whelan, Paul F.
Ghita, Ovidiu
Sezille, Ncolas
Foley, Shane J.
Permanent link: http://hdl.handle.net/10197/7271
Date: Oct-2007
Abstract: The aim of this paper is to present the development of a synthetic phantom that can be used for the selection of optimal scanning parameters in computed tomography (CT) colonography. In this paper we attempt to evaluate the influence of the main scanning parameters including slice thickness, reconstruction interval, field of view, table speed and radiation dose on the overall performance of a computer aided detection (CAD)–CTC system. From these parameters the radiation dose received a special attention, as the major problem associated with CTC is the patient exposure to significant levels of ionising radiation. To examine the influence of the scanning parameters we performed 51 CT scans where the spread of scanning parameters was divided into seven different protocols. A large number of experimental tests were performed and the results analysed. The results show that automatic polyp detection is feasible even in cases when the CAD–CTC system was applied to low dose CT data acquired with the following protocol: 13 mAs/rotation with collimation of 1.5 mm × 16 mm, slice thickness of 3.0 mm, reconstruction interval of 1.5 mm, table speed of 30 mm per rotation. The CT phantom data acquired using this protocol was analysed by an automated CAD–CTC system and the experimental results indicate that our system identified all clinically significant polyps (i.e. larger than 5 mm).
Funding Details: Science Foundation Ireland
Type of material: Journal Article
Publisher: Elsevier
Journal: Medical Engineering and Physics
Volume: 29
Issue: 8
Start page: 858
End page: 867
Copyright (published version): 2006 IPEM
Keywords: CT colonographySynthetic phantomRadiation dosePolyp detection
DOI: 10.1016/j.medengphy.2006.09.005
Language: en
Status of Item: Peer reviewed
metadata.dc.date.available: 2015-12-08T15:18:04Z
Appears in Collections:Medicine Research Collection

Show full item record

SCOPUSTM   
Citations 50

1
Last Week
0
Last month
checked on Dec 12, 2018

Download(s) 50

14
checked on May 25, 2018

Google ScholarTM

Check

Altmetric


This item is available under the Attribution-NonCommercial-NoDerivs 3.0 Ireland. No item may be reproduced for commercial purposes. For other possible restrictions on use please refer to the publisher's URL where this is made available, or to notes contained in the item itself. Other terms may apply.