Now showing 1 - 2 of 2
  • Publication
    Nurses', Physicians' and Radiographers' Perceptions of the Safety of a Nurse Prescribing of Ionising Radiation Initiative: A Cross-Sectional Survey
    Background: A new initiative was introduced in Ireland following legislative changes that allowed nurses with special training to prescribe ionising radiation (X-ray) for the first time. A small number of studies on nurse prescribing of ionising radiation in other contexts have found it to be broadly as safe as ionising radiation prescribing by physicians. Sociological literature on perceptions of safety indicate that these tend to be shaped by the ideological position of the professional rather than based on objective evidence. Objectives: To describe, compare and analyse perceptions of the safety of a nurse prescribing of ionising radiation initiative across three occupational groups: nursing, radiography and medicine. Design: A cross-sectional survey design. Settings: Participants were drawn from a range of clinical settings in Ireland. Sample: Respondents were 167 health professionals comprised of 49 nurses, 91 radiographers, and 27 physicians out of a total of 300 who were invited to participate. Non-probability sampling was employed and the survey was targeted specifically at health professionals with a specific interest in, or involvement with, the development of the nurse prescribing of ionising radiation initiative in Ireland. Methods: Comparisons of perspectives on the safety of nurse prescribing of ionising radiation across the three occupational groups captured by questionnaire were analysed using the Kruskal Wallis H test. Pairwise post hoc tests were conducted using the Mann Whitney U test. Results: While the majority of respondents from all three groups perceived nurse prescribing of ionising radiation to be safe, the extent to which this view was held varied. A higher proportion of nurses was found to display confidence in the safety of nurse prescribing of ionising radiation compared to physicians and radiographers with differences between nurses’ perceptions and those of the other two groups being statistically significant. Conclusion: That an occupational patterning emerged suggests that perceptions about safety and risk of nurse prescribing of ionising radiation are socially constructed according to the vantage point of the professional and may not reflect objective measures of safety. These findings need to be considered more broadly in the context of ideological barriers to expanding the role of nurses.
      664Scopus© Citations 9
  • Publication
    Comparative Analysis of Swept-Source Optical Coherence Tomography and Partial Coherence Interferometry Biometers in the Prediction of Cataract Surgery Refractive Outcomes
    Purpose: To compare the accuracy of pre-operative corneal measurements obtained with four devices, and the refractive outcomes of two optical biometers. Setting: Private practice. Design: Retrospective. Methods: Data taken from biometric measurements on 299 consecutive eyes prior to cataract surgery were retrospectively analyzed using the Argos SS-Optical Biometer and the Lenstar LS900 PCI optical biometer. As part of the standard cataract surgery pre-operative exam, patients also underwent placido disk topography and Scheimpflug tomography. Keratometry, anterior chamber depth, corneal diameter, pupil diameter, central corneal thickness and axial length were all measured. The comparable measurements were compared. Finally, for those eyes where cataract surgery was performed, the post-operative refractive results were compared to the predictive results of the two biometers. Results: The SS-OCT Argos was able to measure all eyes, while five eyes could not be measured with the Lenstar LS900 PCI. Axial length measurements were performed only with the Argos and Lenstar devices. The eyes that could not be measured by the Lenstar LS900 PCI included dense grade IV nuclear sclerosis and large posterior subcapsular cataracts. In the primary endpoints, there was strong correlation between the Argos and the Lenstar devices in eyes with an axial length between 20 and 30 mm. Conclusion: The predictive accuracies of the Argos Optical Biometer and Lenstar LS900 PCI are similar, except in medium and long eyes, in which the predictive accuracy of Argos SS-OCT biometry was higher. The Argos system was found easier to use by technicians when compared to the other biometry devices.
      215Scopus© Citations 8